M. P. Möller (Opus 11817, 1990)

Location:

Church of the Advent, Episcopal
401 N. Union St.
Kennett Square, PA 19348 US
Church
Organ ID: 27573

Update This Entry

Status and Condition:

  • This instrument's location type is: Episcopal and Anglican Churches
  • The organ is unaltered from its original state.
  • The organ's condition is good, in regular use.
We received the most recent update for this instrument's status from Database Manager on May 13, 2018.

Technical Details:

  • Chests: Information unknown or not applicable
  • 59 ranks. 3,357 pipes. 4 divisions. 3 manuals. 52 stops. 44 registers.
All:
  • Position: In a case at the front of the room.
We received the most recent update for this division from Database Manager on May 13, 2018.
Main:
  • Manuals: 3
  • Divisions: 4
  • Stops: 52
  • Registers: 44
  • Position: Movable console.
  • Manual Compass: 61
  • Pedal Compass: 32
  • Key Action: Electrical connection from key to chest.
  • Stop Action: Electric connection between stop control and chest.
  • Console Style: Traditional style without cover.
  • Stop Controls: Drawknobs in vertical rows on angled jambs.
  • Combination Action: Computerized/Digital system.
  • Swell Control Type: Balanced swell shoes/pedals, AGO standard placement.
  • Pedalboard Type: Concave radiating pedalboard meeting AGO Standards.
  • Has Tutti Reversible Thumb Pistons
  • Has Tutti Reversible Toe Pistons
  • Has Combination Action Thumb Pistons
  • Has Coupler Reversible Toe Pistons
We received the most recent update for this console from Database Manager on May 13, 2018.
Database Manager on June 19, 2012:

Updated through online information from Connor Annable.

We received the most recent update for this note from Database Manager on April 09, 2020.

Database Manager on April 06, 2012:

Updated through online information from Jeff Scofield.

We received the most recent update for this note from Database Manager on April 09, 2020.

Database Manager on August 25, 2007:

Identified by Jeff Scofield through information in Möller factory documents.

We received the most recent update for this note from Database Manager on April 09, 2020.
Source not recorded: Open In New Tab Stoplist copied from the factory specifications
We received the most recent update for this stoplist from Database Manager on April 09, 2020.

Instrument Images:

Chancel, Console, and Organ Case: Photograph from <i>The American Organist</i> (October 1991); image courtesy of Jeff Scofield.

Pipe Organs in the Philadelphia area sponsored by:
This instrument has been viewed 829 times.