M. P. Möller (Opus 10370, 1968)

Location:

Trinity United Methodist Church
Huntsville, AL US
Sanctuary
Organ ID: 32550

Update This Entry

Status and Condition:

  • This instrument's location type is: Methodist Churches
  • The organ has been rebuilt or substantially revised.
  • The organ's condition is unknown.
We received the most recent update for this instrument's status from Database Manager on May 13, 2018.

Technical Details:

  • Chests: EP pitman
  • 32 ranks. 1,807 pipes. 4 divisions. 3 manuals. 26 stops. 35 registers.
All:
  • Chest Type(s): EP pitman chests
We received the most recent update for this division from Database Manager on May 13, 2018.
Main:
  • Manuals: 3
  • Divisions: 4
  • Stops: 26
  • Registers: 35
  • Manual Compass: 61
  • Pedal Compass: 32
  • Key Action: Electrical connection from key to chest.
  • Stop Action: Electric connection between stop control and chest.
  • Console Style: Traditional style with roll top.
  • Stop Controls: Drawknobs in vertical rows on angled jambs.
  • Combination Action: Adjustable combination pistons.
  • Swell Control Type: Balanced swell shoes/pedals, AGO standard placement.
  • Pedalboard Type: Concave radiating pedalboard meeting AGO Standards.
  • Has Crescendo Pedal
  • Has Tutti Reversible Thumb Pistons
  • Has Tutti Reversible Toe Pistons
  • Has Combination Action Thumb Pistons
  • Has Combination Action Toe Pistons
  • Has Coupler Reversible Thumb Pistons
  • Has Coupler Reversible Toe Pistons
We received the most recent update for this console from Database Manager on May 13, 2018.
Database Manager on December 29, 2007:

Identified through online information from Jeff Scofield. -- The organ was badly damaged with the nave by the 1989 tornado; it was rebuilt and enlarged by Möller as Op. 11831 for the new (present) nave, retaining 23 ranks.

We received the most recent update for this note from Database Manager on February 11, 2019.
Source not recorded: Open In New Tab Stoplist copied from the factory specifications
We received the most recent update for this stoplist from Database Manager on April 09, 2020.
Factory specifications: Open In New Tab Factory specifications
Document created on 1967-05-22
We received the most recent update for this document from Jeff Scofield on October 12, 2021.

Damage Assessment: Open In New Tab Value of organ, rebuild and removal following 1989 tornado.
Document created on 1989-12-01
We received the most recent update for this document from Jeff Scofield on October 12, 2021.

Instrument Images:

The database contains no images for this instrument. If you have some, please share them using the update entry button on this page.