Pipe Organ Database

a project of the organ historical society

Reuter Organ Co. (Opus 1152, 1955)

Location:

Holy Trinity Lutheran Church
Akron, OH US
Sanctuary
Organ ID: 20968

Update This Entry

Status and Condition:

  • This instrument's location type is: Lutheran Churches
  • The organ has been rebuilt or substantially revised.
  • The organ's condition is unknown.
We received the most recent update for this instrument's status from Database Manager on May 13, 2018.

Technical Details:

  • Chests: Electro-pneumatic (EP)
  • 47 ranks. 2,852 pipes. 5 divisions. 3 manuals. 59 stops. 43 registers.
All:
  • Chest Type(s): Electro-pneumatic (EP) chests
  • Position: In side chambers at the front of the room. Facade pipes or case front visible.
We received the most recent update for this division from Database Manager on May 13, 2018.
Main:
  • Manuals: 3
  • Divisions: 5
  • Stops: 59
  • Registers: 43
  • Position: Console in fixed position, left.
  • Manual Compass: 61
  • Pedal Compass: 32
  • Key Action: Electrical connection from key to chest.
  • Stop Action: Electric connection between stop control and chest.
  • Console Style: Traditional style with roll top.
  • Stop Controls: Drawknobs in vertical rows on angled jambs.
  • Combination Action: Adjustable combination pistons.
  • Swell Control Type: Balanced swell shoes/pedals, AGO standard placement.
  • Pedalboard Type: Concave radiating pedalboard meeting AGO Standards.
  • Has Tutti Reversible Thumb Pistons
  • Has Tutti Reversible Toe Pistons
  • Has Combination Action Thumb Pistons
  • Has Combination Action Toe Pistons
  • Has Coupler Reversible Thumb Pistons
  • Has Coupler Reversible Toe Pistons
We received the most recent update for this console from Database Manager on May 13, 2018.
Database Manager on October 07, 2012:

Updated through online information from Jeff Scofield. -- Retained 25 ranks from 1914 Moller Op. 1575; 8 ranks added by Schantz 1970-1973, with a new Schantz console in 1974.

We received the most recent update for this note from Database Manager on April 09, 2020.

Database Manager on November 21, 2007:

Replaced or Rebuilt by Berghaus, ca. 2000.

We received the most recent update for this note from Database Manager on April 09, 2020.

Database Manager on November 24, 2005:

Identified from the Reuter Opus List, provided by Chris Leaver, Reuter Organ Co., November, 2005.

We received the most recent update for this note from Database Manager on April 09, 2020.
Source not recorded: Open In New Tab Stoplist copied from the factory specifications
We received the most recent update for this stoplist from Database Manager on April 09, 2020.

Instrument Images:

The database contains no images for this instrument. If you have some, please share them using the update entry button on this page.

This instrument has been viewed 419 times.